Avoid Service Checklist
Before calling for service,  review  this  list. It  may  save  you time and expense. This 
list  includes  common occurrences that are  not  the result of defective workmanship 
  OCCURRENCE                        SOLUTION
   Air conditioner will not operate.  Wall plug disconnected. Push plug firmly into wall outlet.
House  fuse  blown  or circuit  breaker  tripped.  Replace fuse with time  delay type or 
reset  circuit breaker.
Selector Control in OFF position. Turn  selector  to  ON (some models) or the desired 
FAN or COOL setting.
Unit  turned  off  by  moving  thermostat  to  a  higher  number  and  then immediately 
turning  back to a colder number. Wait approximately 3 minutes. Listen for compress
or to start.
   Air from unit does not feel cold
   enough.
Turn selector to a higher COOL position
Thermostat set too warm. Set thermostat to colder temperature.
Air conditioner cooling, but
room is too warm- ice forming
on cooling coil behind 
decorative front.
Outdoor  temperature  below  60°F (15°C).  To  defrost  the  coil,  set  selector to FAN 
position. Then, set thermostat to warmer position.
Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set  
selector to FAN .
Thermostat  set  too  cold  for  night-time cooling. To defrost the coil, set selector to a 
FAN position. Then, set thermostat to a warmer position.
Air conditioner cooling, but 
room is too warm-NO ice
forming on cooling coil
behind decorative front.
Dirty air filter-air restricted. Clean air filter. Refer to Care and Cleaning section.
Thermostat set too warm. Turn thermostat clockwise to a colder setting.
Plug current device tripped. Preset RESET  button.
Room temperature below 60°F (15°C). Cooling may not occur until room temperature 
rises above 60°F (15°C).
Temperature  sensing  tube  touching  cold  coil, located  behind  air filter. Straighten 
tube away from coil.
Air   directional  louvers   positioned   improperly.   Position   louvers   for   better   air 
distribution.
Front  of  unit  is  blocked  by  drapes,  blinds,  furniture, etc.-restricts air distribution.
Clear  blockage in front of unit. 
Doors,   windows,  registers,  etc,  open- cold  air  escapes.  Close  doors,  windows,
registers, etc.
Unit  recently  turned  on  in  hot  room,  allow additional time to remove “ stored heat”
from walls, ceiling, floor and furniture.
Air conditioner turns on and 
off rapidly.
Dirty air filter-air restricted. Clean air filter. 
Outside  temperature  extremely  hot.  Set  to  high cool to bring air past cooling coils 
more frequently.
Noise when unit is cooling
Air movement sound. This is normal. If too loud, set to a slower FAN setting.
Sound of  fan  hitting  water-moisture  removal system. This is normal when humidity 
is high. Close doors windows and registers.
Window vibration- poor  installation.  Refer  to  installation instructions or check with 
installer.
Water dripping INSIDE when
unit is cooling.
Improper   installation.  Tilt  air   conditioner  slightly  to  the  outside  to  allow   water 
drainage. Refer to installation instructions - check with installer.
Water dripping OUTSIDE when
unit is cooling.
Unit  removing  large  quantity  of  moisture  from humid room.  This  is normal during
excessively humid days. 
 
or materials in this appliance
Unit  turned  off  and  then  on  too  quickly.  Turn  unit  off  and  wait  3 minutes before 
restarting.
Thermostat set too low. Adjust thermostat to higher number for cooling.