WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the “What to do if you smell gas” instructions.
In the State of Massachusetts, the following installation instructions apply:
■  
Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by 
the State of Massachusetts.
■  
If using a ball valve, it shall be a T-handle type.
■  
A flexible gas connector, when used, must not exceed 3 feet.
5
INSTALLATION INSTRUCTIONS
Tools and Parts
Gather the required tools and parts before starting installation. Read 
and follow the instructions provided with any tools listed here.  
8" or 10" pipe wrench
8" or 10" adjustable wrench 
(for gas connections)
Flat-blade screwdriver
Adjustable wrench that 
opens to 1" (25 mm) or hex-
head socket wrench (for 
adjusting dryer feet)
Level
¼" nut driver or socket 
wrench
Knife
Vent clamps
Pipe-joint compound 
resistant to LP gas
Caulking gun and compound 
(for installing new exhaust 
vent)
Pliers
Parts supplied:
Remove parts package from dryer drum. Check that all parts were 
included.
A
B
C
D
E
A. Leveling legs (4)
B. “Y” connector
C. Short inlet hose
D. Long inlet hose
E. Rubber washer
Parts needed:
Check local codes and consult gas supplier. Check existing gas 
supply, electrical supply, and venting, and read “Electrical 
Requirements,” “Gas Supply Requirements,” and “Venting 
Requirements” before purchasing parts.
Mobile home installations require special parts (listed following) that 
may be ordered by calling the dealer from whom you purchased 
your dryer. For information on ordering, please refer to the 
“Assistance or Service” section. You may also contact the dealer 
from whom you purchased your dryer.
Mobile home installation kit. Ask for Part Number 346764.
Metal exhaust system hardware.
Location Requirements 
You will need
A location that allows for proper exhaust installation. See 
“Venting Requirements.”
A separate 30-amp circuit.