Omnitron FlexPoint 100Fx/Tx 4331-2 プリント

製品コード
4331-2
ページ / 2
800-675-8410 • 949-250-6510  •  www.omnitron-systems.com  •  info@omnitron-systems.com  •  140 Technology Dr. Irvine, CA 92618
© 2010 Omnitron Systems Technology, Inc.  All rights reserved.   FlexPoint is a Trademark of Omnitron Systems Technology, Inc.  
Trademarks are owned by their respective companies.  Specifications are subject to change without notice.
091-04330-004D  9/10
In  this  enterprise  campus  application  example,  FlexPoint 
100Fx/Tx    media  converters  are  installed  in  a  14-Module 
Redundant Power chassis for high-density fiber distribution 
from  UTP  switch  equipment  at  the  Network  Core.   A  UTP 
workgroup switch (A) is connected via fiber with a standalone 
FlexPoint    100Fx/Tx  media  converter.   Another  FlexPoint 
100Fx/Tx  converts  the  fiber  to  UTP  in  a  fiber-to-desktop 
application (B).  An Ethernet switch (C) is connected directly 
via fiber to the FlexPoint module at the Network Core.  In all 
cases, multimode or single-mode fiber can be used, and fiber 
links can be extended up to 120km using single-mode fiber.
sPeCIFICatIONs
aPPlICatION examPle
OrderINg INFOrmatION
Model Type 
100FX/TX
Protocols 
IEEE 802.3, 100BASE-FX, 100BASE-TX
UTP Cable 
EIA/TIA 568A/B, Category 5 and higher
Fiber Cables
Multimode: 50/125, 62.5/125, 100/140µm 
Single-mode: 9/125µm
UTP Connectors
RJ-45 pins 1-2, 3-6 active,  
Categories 3, 4, 5 (EIA/TIA 568)
Fiber Connectors SC, ST, VF-45, MT-RJ
Switches 
UTP crossover, UTP A/N, FDX/HDX 
LED Displays
Power:  Yellow LED = Power Applied 
Auto-Negotiation:  Green LED = A/N Enabled 
Full-Duplex:  Green LED = FDX Selected 
Half-Duplex:  Green LED = HDX Selected 
Fiber/Link Receive:  Green LED = Link/Data Received 
Fiber Error:  Red LED = Fiber Data Error 
UTP/Link Receive:  Green LED = Link/Data Received 
UTP Error:  Red LED = UTP Data Error
Dimensions 
W: 3.0" x D: 4.0" x  H: 1.0"
Weight
 6 oz. (without power adapter)
Compliance 
UL, CE, FCC Class A
Power 
 Requirements
 
Nominal Voltage: 
Voltage Range: 
Power Nominal: 
Maximum Power:
Barrel Connector 
9VDC 
6.0 to 15.0VDC 
0.3A @ 9VDC 
1A @ 9VDC
Molex Connector 
5VDC 
4.75 to 5.25VDC 
0.5A @ 5VDC 
0.75A @ 5VDC
Temperature
0 to 50
o
 C
Humidity 
5 to 95% (non-condensing)
Altitude 
-100m to 4000m
MTBF (Hours) 
Module without Power Adapter: 93,000 
Module with Power Adapter 
-1: 250,000 
Module with Power Adapter 
-2: 100,000
Fiber Type
Distance
Connector Type
Tx / Rx 
Wavelength 
[nm]
Min. Tx 
Power 
[dBm]
Max. Tx 
Power 
[dBm]
Min. Rx 
Sense 
[dBm
Max. Rx 
Power 
[dBm]
Optical Power 
Budget
ST
SC
MT-RJ
VF-45
MM
5km
4332-x
4330-x
4336-x
4338-x
1310
-24
-14
-31
-14
7
SM
30km
4333-x
4331-x
4337-x
-
1310
-15
-8
-31
-8
16
SM
60km
4335-x
4334-x
-
-
1310
-5
0
-31
-3*
26
SM
120km
-
4351-x
-
-
1550
-5
0
-31
-3*
26
Power Adapter Kits (-x):  -0 = No power adapter included, -1 = 110-120 VAC/60 Hz (US plug),  -2 = 100-240 VAC/50-60 Hz (IEC plug, no power cord)     
Contact Omnitron for other fiber options and operational temperature ranges 
*When using these models in pairs, a minimum attenuation of 3dB is required.