KitchenAid 24" Panel Ready Beverage Center with Glass Door 使用とお手入れ

ページ / 44
4
INSTALLATION REQUIREMENTS
Tools and Parts
Tools Needed
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.
Parts Needed 
Parts Supplied
Location Requirements
To ensure proper ventilation for your beverage center, allow for a 
¹⁄₄" (6.35 mm) space on each side and at the top. When installing 
your beverage center next to a fixed wall, leave 2
¹⁄₂" (6.35 cm) 
minimum clearance on the hinge side to allow for the door to 
swing open. 
NOTE: It is recommended that you do not install the beverage 
center near an oven, radiator, or other heat source. Do not install 
in a location where the temperature will fall below 55°F (13°C). For 
best performance, do not install the beverage center behind a 
cabinet door or block the base grille.
Opening Dimensions
Height dimensions are shown with the leveling legs extended 
to the minimum height.
NOTE: When leveling legs are fully extended, add 
⁵⁄₈" (15 mm) 
to the height dimensions.
If the floor of the opening is not level with the kitchen floor, 
shim the opening to make it level with the kitchen floor.
Custom Overlay Frame
If you plan to install a custom overlay frame, you will need to 
create the frame yourself or consult a qualified cabinetmaker or 
carpenter. See dimension drawings for frame specifications.
IMPORTANT: 
The thickness of the overlay frame must be 
³⁄₄" (19 mm).
The overlay frame must not weigh more than 10 lbs (4.54 kg). 
Overlay frames weighing more than recommended may 
cause damage to your appliance.
Overlay frame drawings show the rear view of the frame.
Cordless drill
¹⁄₁₆" and ³⁄₈" Brad point 
doweling drill bit
Phillips screwdriver
Rotary tool
Scissors
C-clamp
Masking tape
Tape measure
Petroleum jelly
Custom Overlay Frame—See “Overlay Frame—Rear 
View.”
Flat-head screws (TRUSS M4x34 Tapping) (8)
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as 
gasoline, away from beverage center.
Failure to do so can result in death, explosion, or fire.
 
¹⁄₄
" (6.35 mm)
2
¹⁄₂
" (6.35 cm)
Critical Dimensions:
A. 14
³⁄₄
" (37.5 cm) utility opening
B. 24" (60.96 cm) minimum opening width
¹⁄₂
"
(1.3 cm)
A
14
³⁄₄
"
(37.5 cm)
24"
(60.96 cm)
min.
24" (60.96 cm) min.
34
³⁄₈
" (87.3 cm) min.
35" (88.9 cm) max.
B