KitchenAid 20.8 Cu. Ft. 36" Width Built In Panel Ready French Door Refrigerator インストールガイド

ページ / 72
7
The water shutoff should be located in the base cabinet on 
either side of the refrigerator or some other easily accessible 
area. If the water shutoff valve is not in the cabinets, the 
plumbing for the water line can come through the floor or 
the back wall. See “Water Supply Requirements” for more 
specific information.
NOTE: Flooring under refrigerator must be at same level as the 
room.
Electrical Requirements
Before you move your refrigerator into its final location, it is 
important to make sure you have the proper electrical 
connection.
Recommended Grounding Method
A 115 volt, 60 Hz., AC only, 15- or 20-amp fused, grounded 
electrical supply is required. It is recommended that a separate 
circuit serving only your refrigerator be provided. Use an outlet 
that cannot be turned off by a switch. Do not use an 
extension cord.
IMPORTANT: If this product is connected to a GFCI (Ground 
Fault Circuit Interrupter) protected outlet, nuisance tripping of the 
power supply may occur, resulting in loss of cooling. Food quality 
and flavor may be affected. If nuisance tripping has occurred, 
and if the condition of the food appears poor, dispose of it. 
NOTE: Before performing any type of installation or cleaning, 
remove the top grille and turn the master power switch to OFF 
or disconnect power at the circuit breaker box. 
When you are finished, turn ON the master power switch or 
reconnect power at the circuit breaker box. Then reset the control 
to the desired setting. 
Water Supply Requirements
All installations must meet local plumbing code requirements.
The water shutoff should be located in the base cabinet on 
either side of the refrigerator or some other easily accessible 
area. The right-hand side is recommended. The access hole 
through the cabinet must be within 
¹⁄₂" (1.3 cm) of the rear wall.
NOTE: If the water shutoff valve is in the back wall behind the 
refrigerator, it must be at an angle so that the tube is not 
kinked when the refrigerator is pushed into its final location.
Model
Width A
(as shown above)
Dimension B 
(as shown above)
36"
35
¹⁄₂" to 35³⁄₄" 
(90.2 cm to 90.8 cm) 
4" (10.2 cm)
42"
41
¹⁄₂" to 41³⁄₄" 
(105.4 cm to 106 cm)
7
¹⁄₂" (19 cm)
80" - 90"
(203-229 cm) 
6"
(15.2 cm)
83
¹⁄₂
" (212.1 cm) min.
84
³⁄₄
" (215 cm) max.
to bottom of solid soffit
24"
(60.96 cm) min. 
1"
(2.54 cm) 
77"
(196 cm)
6"
(15.2 cm)
6"
(15.2 cm)
A
Width
(see chart following)
B
Dimension
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING
24"
(60.96 cm) min. 
1"
(2.54 cm) 
6"
(15.2 cm)
6"
(15.2 cm)
6"
(15.2 cm)