Sony HDW-S280 ユーザーズマニュアル

ページ / 92
31
Basic Operations of the Function Menu
  Chapt
er
 3
   
P
rep
ar
at
ions
P2 VIDEO page
P3 AUDIO page
SETUP/
BLACK
Sets the setup level (59.94i mode) or black 
level (50i mode) of the HD/SD output signal.
PRESET: Regardless of manually set values, 
the level is set to the standard value.
Manual setting: With the displayed setting 
flashing, you can adjust the setup level 
across the range ±30 IRE (59.94i mode) 
or adjust the black level across the range 
±210 mV (50i mode) by rotating the 
MULTI CONTROL knob.
Y/C DELY
Sets the Y/C delay during playback of an 
analog Betacam cassette.
PRESET: Regardless of manually set values, 
the Y/C delay is set to the standard value.
Manual setting: With the displayed setting 
flashing, you can adjust the Y/C delay 
across the range ±100 ns by rotating the 
MULTI CONTROL knob.
Item
Setting
VIDEO IN
Selects the input video signal.
SDI: HD SDI signal
SG: Test signal generated by the internal test 
signal generator (To select SG, hold the 
corresponding function button pressed for 
more than three seconds.)
OUT REF
Selects the reference signal of this unit, 
according to the settings of setup menu items 
309 and 334, and the operating state of this 
unit.
REF: Use the signal input to the REF INPUT 
connector as the reference signal. During 
recording, input digital audio signals and 
video signals must be synchronized with 
this signal.
INPUT: Use the input video signal as the 
reference signal.
SYNC
Sets the SD/HD output signal sync phase.
Setting method 
Press the SYNC function button then rotate 
the MULTI CONTROL knob to adjust the 
output signal sync phase with the displayed 
setting flashing. The adjustable range is 
±15 µs relative to the input reference signal. 
Adjust this item if you wish to adjust the 
output signal sync phase precisely to match a 
reference signal or when connecting this unit 
and other VTRs to a device such as a 
switcher to perform operations such as 
special effects editing.
Item
Setting
SC
Sets the SD/HD output signal subcarrier 
phase.
Setting method 
Press the SC function button then rotate the 
MULTI CONTROL knob to adjust the output 
signal subcarrier phase with the displayed 
setting flashing. The adjustable range is 
±200 ns relative to the input reference signal.
Adjust this item when you are using 
composite signals in editing and wish to 
adjust the output signal subcarrier phase 
precisely to match a reference signal. Even 
when this value is adjusted, the output SCH 
(subcarrier to sync) phase is maintained. 
Item
Setting
AUDIO IN
Selects an audio input signal. The selected 
signal is shown at INPUT in the audio data 
area.
ANALOG: Analog audio signal
SDI: SDI signal
SG: SG signal
MONITR L
Selects an output signal from the AUDIO 
MONITOR OUTPUT L connector (CH1/CH2/
CH3/CH4/CUE). The selected signal is 
shown at MONI L in the audio data area.
MONITR R
Selects an output signal from the AUDIO 
MONITOR OUTPUT R connector (CH1/CH2/
CH3/CH4/CUE). The selected signal is 
shown at MONI R in the audio data area.
LEVEL MT
Sets the audio level meter displayed on the 
video monitor display.
LEFT: Display the audio level meter on the 
left of the video monitor display.
RIGHT: Display the audio level meter on the 
right of the video monitor display.
LEFT (4): Displays the four-channel audio 
level meters on the left of the video 
monitor display.
RIGHT (4): Displays the four-channel audio 
level meters on the right of the video 
monitor display.
OFF: Not display the audio level meter.
EMPHASIS Specifies whether to add audio emphasis to 
analog audio input signals and Betacam/
Betacam SP format playback audio signals.
ON: Add audio emphasis.
OFF: Do not add audio emphasis.
DOLBY NR When using oxide tapes, this is to specify 
whether or not to use the Dolby type C low-
frequency noise reduction (NR) system.
ON: Use the Dolby NR system when playing 
back analog Betacam oxide tapes.
OFF: Do not use the Dolby NR system when 
playing back analog Betacam oxide tapes.
Item
Setting