McIntosh 7205thx ユーザーズマニュアル

ページ / 12
5
Installation
The MC7205 can be placed upright on a table or shelf,
standing on its four feet. It also can be custom installed in a
piece of furniture or cabinet of your choice. The required
panel cutout, ventilation cutout and unit dimensions are
shown.
Always provide adequate ventilation for your MC7205.
Cool operation ensures the longest possible operating life
for any electronic instrument. Do not install the MC7205
directly above a heat generating component such as a high
powered amplifier. If all the components are installed in a
single cabinet, a quiet running ventilation fan can be a defi-
nite asset in maintaining all the system components at the
coolest possible operating temperature.
Installation
17-1/2"
444mm
17-1/16"
433.4mm
7/32"
5.3mm
Support Shelf
Outline of Front Panel
Edge of Cutout
Panel Height
  7.00"  
 177.8mm
   6-9/16"  
  166.7mm
1/4"
6mm
3/16"
5.1mm
End Caps
7-1/16"
179.8mm
Bottom of Cutout and Top
of Support Shelf Must
Coincide
Mounting Surface
Outline of Unit
(Side View)
Support Shelf
Mounting Bracket at Both Sides of the Rear Panel.
Fasten with 6-32 x 3/8 Machine Screw and Washer to Chassis.
Fasten with 6 x 1/2 Wood Screw and Washer to Support Shelf
6"
15"
9"
Mounting Surface
Cut Out Center
for Ventilation
(Bottom View)
(Front View)
Cut Out Center
for Ventilation
Front View of a MC7205
custom installed
A custom cabinet installation should provide the follow-
ing minimum spacing dimensions for cool operation. Allow
at least 2 inches (5.1 cm) above the top and 1 inch (2.54
cm) on each side of the amplifier, so that airflow is not ob-
structed. Allow 21 inches (53.3 cm) depth behind the
mounting panel, which includes clearance for connectors.
Allow 1-1/8 inches (2.9 cm) in front of the mounting panel
for knob clearance. Be sure to cut out a ventilation hole in
the mounting shelf according to the dimensions in the
drawing.
Side View of a MC7205
custom installed
Bottom View of a MC7205
custom installed