The only function key here that needs to be explained is PRINT SCREEN (F5) which will
print out a hard copy of the screen shown.
Each parameter can be adjusted one of three ways:
The UP arrow key will increase the parameter value.  The DOWN arrow key will 
decrease the parameter value.
The PGUP key will increase the parameter with a rate increase of 10 times its present  value.
The PGDN key will decrease the rate of decrease by 10  times its present value.
In the following sections below, each alignment parameter with its proper aligning procedures
are explained.
1.
Scan Monitor Hold Time
Monitor Hold Time determines how long the radio will remain on the monitored channel once
the monitor button is released.  During monitor hold time, squelch and PL are not defeated
unless permanent monitor has been engaged.  After Monitor Hold Time expires, permanent
monitor is released and normal channel scan resumes.  To align this scan parameter, follow
the steps below:
(a) Set up according to Section VI-A, Fig. 8 and select the SCAN MONITOR HOLD TIME
option in the Align Scan Menu.
(b) Increment or decrement the time parameter accordingly using the UP (or PGUP) or the
DOWN (or PGDN) arrow keys.  
(c) Valid time range is from $01 to $3C (1 to 60 seconds) with a default value of $03 or 3
seconds.
(d) Reprogram radio if finished with ALL alignment functions.
Servicing the Radio
34