Honeywell D ユーザーズマニュアル

ページ / 8
69-0917—2
4
T8112C,D ELECTRONIC PROGRAMMABLE THERMOSTATS
M1712A
JUMPER (FACTORY-
INSTALLED) REMOVE 
IF 5-WIRE SYSTEM
INSERT
STRAIGHT 
UNDER 
SCREW HEAD
5/16 in. 
(8 mm)
STRIP 
END OF WIRE 
VISIBLE HERE
R
Rc
W
Y
G
M3002A
T8112C
M5780
B.
  
PRESS LOWER EDGE 
      OF CASE TO LATCH.
A.
  
ENGAGE TABS AT TOP OF 
      THERMOSTAT AND MOUNTING PLATE.
TU
AM
LEAVE 
Fig. 8. Proper wiring technique.
Fig. 9. Holding thermostat while installing.
Mounting Thermostat on Mounting Plate
1. Engage tabs at the top of thermostat and mounting
plate. See Fig. 10.
2. Press lower edge of case to latch.
NOTE:
To remove the thermostat from the wall, first
pull out at the bottom of the thermostat; remove
top last.
T8112D
Fig. 10. Mounting thermostat on mounting plate.
M13063
B.
  PRESS LOWER EDGE 
       OF CASE TO LATCH.
C.
  SWING COVER OPEN TO 
       CHECK OPERATION.
A.
  ENGAGE TABS AT TOP OF 
       THERMOSTAT AND MOUNTING PLATE.