honda-power-equipment eu3000is ユーザーズマニュアル

ページ / 71
58
STORAGE
STORAGE TIME
RECOMMENDED SERVICE PROCEDURE TO
PREVENT HARD STARTING
Less than 1 month
1 to 2 months
2 months to 1 year
1 year or more
Before storing the unit for an extended period:
1. Be sure the storage area is free of excessive humidity and dust.
2. Service according to the table below:
Use gasoline stabilizers that are formulated to extend storage
life.
Contact your authorized Honda generator dealer for gasoline
stabilizer recommendations.
No preparation required
Fill with fresh gasoline and add gasoline
stabilizer .
Fill with fresh gasoline and add gasoline
stabilizer .
Drain the carburetor float bowl (page 59).
Drain the fuel sediment cup (page 48).
Fill with fresh gasoline and add gasoline
stabilizer .
Drain the carburetor float bowl (page 59).
Drain the fuel sediment cup (page 48).
Remove the spark plug. Put a tablespoon of
engine oil into the cylinder. Turn the engine
slowly with the starter grip to distribute the
oil. Reinstall the spark plug.
Change the engine oil (page 43).
After removal from storage, drain the stored
gasoline into a suitable container, and fill
with fresh gasoline before starting.
07/01/11 13:58:43 31ZT7600_059