5.3.4  Category 4, Altitude Callouts
The following table provides identification of the Altitude Callouts Menu.  Each entry in the ID column corresponds to a
particular menu selection. The Altitude Callouts menu ID’s 0 through 12 consist of standard callouts.  Selecting ID 0 – 12
will result in the callouts listed being enunciated.
Smart 500 activation is reflected by a “500” callout being spoken at the end of the selected callout menu sequence in the
Long Level 1 Self-Test.  In addition, the Callout menu ID number and the “Smart Callout Selected” configuration
message, will both be given during level 3 Self-Test and in the RS232 Present Status display.
Table 5.3.4: Altitude Callouts
ID
MENU
Smart
Callout
Software
Effectivity
EGPWS
Selected
MKVI
MK VIII
0
 MINIMUMS-MINIMUMS,
“Smart 500”, 200, 100, 50, 40, 30, 20 ,10
 True
 -020
 X
 X
1
 MINIMUMS-MINIMUMS,
“Smart 500”, 200
 True
 -020
 X
 X
2
 MINIMUMS-MINIMUMS,
“Smart 500”, 100, 50, 40, 30, 20 ,10
 True
 -020
 X
 X
3
 MINIMUMS-MINIMUMS,
 “Smart 500”
 True
 -020
 X
 X
4
1
 MINIMUMS-MINIMUMS,
200, 100, 50, 40, 30, 20 ,10
 False
 -020
 X
 X
5
1
 MINIMUMS-MINIMUMS,
 200
 False
 -020
 X
 X
6
1
 MINIMUMS-MINIMUMS,
100, 50, 40, 30, 20 ,10
 False
 -020
 X
 X
7
1
 (no callouts)
 
 False
 -020
 X
 X
8
1
 MINIMUMS-MINIMUMS
 
 False
 -020
 X
 X
9
 MINIMUMS-MINIMUMS,
500, 200, 100, 50, 40, 30, 20 ,10
 False
 -020
 X
 X
10
 MINIMUMS-MINIMUMS,
 500, 200
 False
 -020
 X
 X
11
 MINIMUMS-MINIMUMS,
500, 100, 50, 40, 30, 20 ,10
 False
 -020
 X
 X
12
 MINIMUMS-MINIMUMS,
 500
 False
 -020
 X
 X
13
 MINIMUMS,
 1000, 500, 400, 300, 200, 100, 50, 40, 30, 20, 10
 False
 -020
 X
 X
14
1
 MINIMUMS-MINIMUMS,
 100
 False
 -020
 X
 X
15
1
 MINIMUMS-MINIMUMS,
 200, 100
 False
 -020
 X
 X
100
2
 Above Field Callout “500”
 False
 -020
 X
 X
101
2
 Above Field Callout “500 Above”
 False
 -020
 X
 X
1  Compliance with TSO-C151a requires a "500" callout.  These IDs cannot be used on installations requiring compliance with TSO-C151a unless
there is an alternate source of the "500" callout.
2  This ID provides Above Field Callout. Geometric altitude and runway database are used to calculate the height above field. If this ID is selected
TA&D and TCF must be enabled (MK VI and MK VIII installations cannot select Category 6 ID 2).
Note:
Selecting an Altitude Callout ID without a minimums callout can be accomplished by leaving the Decision Height (DH) input discrete open.