Honeywell MK VIII ユーザーズマニュアル

ページ / 326
Honeywell
MK VI  MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896
SCALE: NONE
SIZE: A
DWG NO: 060-4314-150
REV:
SHEET 
22
1.9.4 Annunciato rs & Switch/Annunciators
The devices shown below are West Coast Specialties and Staco switch/annunciators and are representative of
those used in some installations. However, there are other comparable devices on the market that may be
substituted at the installer/customers choice. The installer/customer is cautioned to verify regulatory
approval of the annunciation devices installed.
 See Appendix D for Vendors.
A.  GPWS (P/TEST); BELOW G/S (P/CANCEL) switch/annunciator assemblies
The ‘GPWS’ annunciator provides visual indication of an EGPWS warning or alert. The GPWS annunciator
also has a momentary switch that is used to manually initiate EGPWS Self Test.  Two GPWS annunciators
are required for each aircraft, one in the direct view of each pilot.  If the Lamp Format 2 option is selected
(see 3.15.2.1), this switch/annunciator will be labeled ‘PULL UP’ and annunciated in red.
The ‘BELOW G/S’ annunciator provides visual indication of an EGPWS glideslope caution. The BELOW
G/S annunciator also has a momentary switch that is used to manually inhibit EGPWS Mode 5 glideslope
alerts. Two BELOW G/S annunciators are required for each aircraft, one in the direct view of each pilot.  If
the Lamp Format 2 option is selected (see 3.15.2.1), this switch/annunciator will be labeled ‘GPWS’ and
annunciated in amber.
Vendor Name
Vendor P/N
Description
QTY UM
West Coast Spec.
90-81401-001
GPWS   BELOW G/S
2
EA
West Coast Spec.
90-81401-003
GPWS   BELOW G/S
ALT
EA
West Coast Spec.
90-81401-008
GPWS   BELOW G/S
 (1)
ALT
EA
West Coast Spec.
90-81401-009
GPWS   BELOW G/S
 (1)
ALT
EA
STACO
61406-003
GPWS  
G/S CANCEL
ALT
EA
STACO
61406-004
PULL UP  
GPWS TEST
ALT
EA
STACO
61406-005
GPWS  
GPWS TEST
ALT
EA
STACO
61406-006
BELOW G/S  
G/S CANCEL
ALT
EA
(1) GPWS – BELOW G/S – GPWS FLAP OVRD – G/S CANCLD
B.  GPWS FLAP OVRDGPWS INOPG/S CANCLD switch/annunciator assemblies
The ‘GPWS FLAP OVRD’ annunciator provides visual indication that the EGPWS Flap Override function is
activated. The GPWS FLAP OVRD annunciator also has a momentary switch that is used to manually activate
the Flap Override function.
The ‘GPWS INOP’ annunciator provides visual indication that the EGPWS’ GPWS modes have been disabled
or do not function because of an external or internal fault.
The ‘G/S CANCLD’ annunciator provides visual indication that the EGPWS Mode 5 function is inhibited.
Vendor Name
Vendor P/N
Description
QTY UM
West Coast Spec.
90-81401-008
(1)
1
EA
West Coast Spec.
90-81401-009
(2)
1
EA
West Coast Spec.
90-81401-010
(3)
1
EA