T8611M DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS
5
69-1415—1
Fig. 8. T8611M System and Fan key locations.
LED Indication
Two LED indicators are located in the upper right of the 
thermostat. They indicate when a CHECK or FAIL signal 
is sent to the thermostat from the system. See Fig. 9. The 
CHECK LED is on continuously when the thermostat 
system setting is in the Emergency Heat position.
.
Fig. 9. LED location.
Temperature Settings
Refer to Table 2 for the default program settings. If the 
daytime energy savings period is not used, press the 
period key (Leave or Return) until the time is blank. The 
fan setting feature is available on select thermostat 
models. See Owner’s Guide for complete instructions on 
changing the program.
Table 2. Default Program Settings.
INSTALLER SETUP
NOTE: For most applications, the thermostat factory-
settings will not need to be changed. Review 
the factory settings in Table 2 and if no changes 
are necessary, go to the Installer System Test 
section.
The Installer Setup is used to customize the thermostat 
to specific systems. Some of the options include 
temperature display, changeover and outdoor 
temperature display. Installer Setup numbers are listed in 
Table 3. The table includes all the configuration options 
and the factory settings for the T8611. 
A combination of key presses are required to use the 
Installer Setup feature:
— To enter the installer setup, press and hold the 
information i key with the increase s and decrease t 
keys until the first number is displayed. All display 
segments appear for approximately three seconds 
before the number is displayed. See Fig. 10 and 11.
— To advance to the next Installer Setup, press the 
Time 
 key.
— To change a setting, use the increase s or 
decrease t key.
— To scroll the Installer Setup numbers backward, press 
the Time 
 key.
— To exit the Installer Setup, press Run Program.
Fig. 10. Display of LCD segments.
Fig. 11. Display of Installer Setup 
number and setting.
IMPORTANT
Only configurable numbers are shown on the 
device. Example: If thermostat does not have a 
system key, Installer Setup Number 12 will not 
be displayed. Review Table 3 factory settings 
and mark any desired changes in the Actual 
Setting column. When Installer Setup is 
complete, review the settings to confirm that 
they match the system.
Period
Time
Heat 
Setpoint
Cool 
Setpoint
Fan 
Setting
Wake
6:00 AM
70°F
(21°C)
78°F
(25.5°C)
Auto
Leave
8:00AM
62°F
(16.5°C)
85°F
(29.5°C)
Auto
Return
5:00 PM
70°F
(21°C)
78°F
(25.5°C)
Auto
Sleep
10:00 PM
62°F
(16.5°C)
82°F
(28°C)
Auto
M14625
Hold Temp
Run
Program
Copy
Daylight
Time
Set Current
Day/Time
System
Fan
Time
Set Program
Day
System
Fan
Wake
Leave
Return
Sleep
Heat/Cool
Settings
M10675A
TWO LED INDICATORS
M14559
Aux Ht
Set Day/Time
Set Program
Mon
Wake Leave Return
Sleep
Outdoor
Room
Filter
Wait
System
Fan
Em Heat
On
Auto
Off
Cool
Auto
AM
PM
Hold for
Heat
Cool
Repl Batt
Recovery
DST
Tue Wed Thu Fri Sat Sun
Days
Temporary
Setting
Em Ht
M14618
INSTALLER SETUP
NUMBER DISPLAY
(COLUMN 2 OF TABLE 3)
FACTORY SETTING OR OTHER 
CHOICE DISPLAY (COLUMN 3
OR 5 OF TABLE 3)