Installation
2. Configure the following behavior settings: 
3. Configure the following action settings: 
Note
Remember to select APPLY and click 
 to save all settings before exiting 
these menus.
Configuring Buzzer Out Settings
1. Click BUZZER OUT on the left side of the EVENT/SENSOR window.
The BUZZER OUT setup menu appears.
ALARM OUT
Choose to configure a specific alarm output.
OPERATION
Enable/disable the selected alarm output.
MODE
Select from TRANSPARENT (the output is active only when the 
trigger criteria are present) or LATCHED (the output is active for 
a set period of time after a trigger). 
DURATION
In LATCHED mode, this is the time that the alarm output remains 
active after it has been triggered. 
TYPE
Select from HIGH (0V to +5V when activated) or LOW (+5V to 0V 
when activated). 
HDD EVENT
Determines whether a hard drive event triggers the alarm output. 
ALARM
Configure whether the alarm inputs trigger the alarm output. 
VIDEO LOSS
Configure whether video loss on any of the selected channels 
triggers the alarm output. 
MOTION
Configure whether motion detection on any of the selected 
channel triggers the alarm output.