Cissell cissiman38 ユーザーズマニュアル

ページ / 36
Page 21
Page 21
Page 21
Page 21
Page 21
CA
CA
CA
CA
CAUSE
USE
USE
USE
USE
10A Steam valve linkage not
properly adjusted
10B Steam time set too short
11
Defective steam timer
12A Defective Air timer
12B Defective blower relay
12C Defective automatic relay
13A Damper control rod
disconnected or broken
REMEDY
REMEDY
REMEDY
REMEDY
REMEDY
Adjust linkage according to
adjustment instructions.  Tighten
all set screws and lock nuts.
Set steam timer for longer time.
Tighten knob set screw if
necessary.
Check timer operation.  See if
timer switch operates properly.  If
operation is not correct, replace
the timer.
Check timer operation.  See if
timer switch operates properly.  If
operation is not correct, replace
the timer.
Check to see if relay operates
properly on rated current.  If
contacts are stuck or welded shut,
or relay does not operate properly,
replace it.
Check relay operation to see that
contacts alternate from closed to
open.  Also, be sure that relay will
operate on rated current.  If not,
replace relay.
Check to see that the damper
opens and closes when the control
knob is lowered and raised.  If not,
repair or replace damper control
rod.
PROBLEM
PROBLEM
PROBLEM
PROBLEM
PROBLEM
(10) Inadequate steam flow
(11) Blower motor will
(12) Blower motor won’t stop
(13) Blower motor starts, but
form will not change