Honeywell chronotherm iv t8611g ユーザーズマニュアル

ページ / 12
T8611G CHRONOTHERM
®
 IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS
5
69-1406—1
Adaptive 
Intelligent 
Recovery™ 
control.
13
0
Adaptive Intelligent 
Recovery™ 
control is activated 
(system starts 
early so setpoint is 
reached by start of 
program period).
1
Conventional recovery 
(system starts recovery at 
programmed time).
Degree 
temperature 
display
14
1
Temperature is 
displayed in °C
Temperature is displayed in 
°C
Not Used.
15
Clock format.
16
0
12-hour clock 
format.
1
24-hour clock format.
Not Used.
17 thru 23
Outdoor 
temperature 
display (models 
with OT 
terminals).
24
0
No outdoor 
temperature is 
displayed.
1
Outdoor temperature is 
displayed. Needs a 
C7089B1000 Outdoor 
Temperature Sensor to 
operate.
Not Used.
25 thru 28
O/B terminal 
energized in 
heating or 
cooling.
29
0
O/B terminal 
energized for 
reversing valve in 
cooling.
1
O/B terminal energized for 
reversing valve in heating
Deadband
30
3
Heating and 
cooling setpoints 
can be set no 
closer than 3°F 
(1.5°C).
4 thru 10 Heating and cooling 
setpoints can be set no 
closer than the chosen 
value:
4—4°F (2°C)
5—5°F (2.5°C)
6—6°F (3°C)
7—7°F (3.5°C)
8—8°F (4°C)
9—9°F (4.5°C)
10—10°F (5°C)
Not Used.
31 and 32
Minimum off 
time for the 
compressor.
33
5
5 minute minimum 
off time for the 
compressor.
0 thru 4
Minimum number of minutes 
(0 thru 5) the compressor 
will be off between calls for 
the compressor.
Temperature 
range stops in 
heating.
34
90
Highest heating 
setpoint setting.
40 thru 89 Temperature range (1°F 
increments) of heating 
setpoint settings.
Temperature 
range stops in 
cooling.
35
45
Lowest cooling 
setpoint  setting.
46 thru 99 Temperature range (1°F 
increments) of cooling 
setpoint settings
Not Used.
36
Table 3. Thermostat Installer Setup Options. (Continued)
Select
Installer Setup 
Number (Press 
Time 
 key to 
change)
Factory Setting
Other Choices
(Press  or  key to change)
Actual 
Setting
Display
Description
Display
Description