Fujitsu MHR2020AT ユーザーズマニュアル

ページ / 40
Maintenance and Diagnosis
1.1  Maintenance
C141-F055-01EN
1-3
1.1.2 Maintenance requirements
(1) Preventive maintenance
The disk drive needs no preventive maintenance, not even the air filter needs to be
changed.
Device damage
The DE is completely sealed.  Do not open the DE in the field.
(2) Service life
In situations where management and handling are correct, the life of the disk drive
is five years when the DE surface temperature is less than 48°C.  When the DE
surface temperature exceeds 48°C, the life is five years or 20,000 hours of
operation, whichever occurs first.  Refer to Section 1.7 and 3.2 in Product
Manual.
(3) Exchangeable parts in field
The PCA and the DE cannot be replaced separately in the field.  Replace the
whole disk drive.
(4) Service system and repair
Fujitsu Limited has a disk drive service system and repair facility.  When making
a request for repair or parts replacement, you should provide related information
usually including:
a)
Model name of disk drive, part number (P/N), disk drive revision number,
manufacture serial number (S/N), and date of manufacture of the disk drive
b)
Circumstances when the fault occurred
 
Date of trouble occurred
 
System configuration
 
Environmental conditions (including temperature, humidity, and voltage)
c)
Fault history of the drive
d)
Details of the fault
 
Description of the fault
 
Issued command and specified parameters
 
Status (Status/Error register)
 
Interval of the fault
 
Other information for fault diagnosis