MTI Co. Ltd. RF25-MWM101 ユーザーズマニュアル

ページ / 36
 
 
 
 
 
 
 
 
BDA Installation and Operating Guide 
Version 1.0                                                                          21 
 
 
z
  Feed -55dBm/total of WiMAX signal (using a signal generator) to ‘LINK ANT’ port 
of BDA and adjust gain(75dB max) in the DOWNLINK (UPLINK) path, so that the 
output power of the BDA becomes +20dBm. Access the BDA and check if output 
power of the BDA is +20dBm. If not, adjust gain in the DOWNLINK (UPLINK) 
path. 
z
  If you don’t want maximum output power(+20dBm), decrease DOWNLINK gain or 
UPLINK gain. 
z
  Set difference between gain of down link and gain of up link (AGD). If don’t need 
difference between down link and up link, set “0”. 
z
 Temperature 
alarm 
threshold. 
z
  If the parameters have proper value, enable HPA and UDC module. 
z
  Check if the alarm generated or not.