MTI Co. Ltd. RF25-MWM101 ユーザーズマニュアル
BDA Installation and Operating Guide
Version 1.0 21
z
Feed -55dBm/total of WiMAX signal (using a signal generator) to ‘LINK ANT’ port
of BDA and adjust gain(75dB max) in the DOWNLINK (UPLINK) path, so that the
output power of the BDA becomes +20dBm. Access the BDA and check if output
power of the BDA is +20dBm. If not, adjust gain in the DOWNLINK (UPLINK)
path.
output power of the BDA becomes +20dBm. Access the BDA and check if output
power of the BDA is +20dBm. If not, adjust gain in the DOWNLINK (UPLINK)
path.
z
If you don’t want maximum output power(+20dBm), decrease DOWNLINK gain or
UPLINK gain.
z
Set difference between gain of down link and gain of up link (AGD). If don’t need
difference between down link and up link, set “0”.
z
Temperature
alarm
threshold.
z
If the parameters have proper value, enable HPA and UDC module.
z
Check if the alarm generated or not.