7.7.2  ADDING RFPS FOR CONFIGURATION 
Before you can configure an RFP, you must add the RFP to the OM Configurator database. You can add 
an RFP record by:  
• 
scanning for RFPs that are already attached to the network 
• 
entering the MAC address of the RFP 
• 
loading a configuration file that contains RFP MAC addresses and configuration parameters 
Please note: 
Adding an RFP to the OM Configurator database does not modify the RFP 
configuration. Configuration data must be transmitted explicitly to the RFP(s) through the 
Send Configuration option. 
 
7.7.3  SCANNING FOR RFPS 
The OM Configurator tool can scan for RFPs on the LAN segment. 
 
• 
If 
get configuration after detecting an RFP is enabled, the OM Configurator attempts to fetch the 
local configuration settings from all RFPs that are detected during the scan. The program uses the 
user/password combination if an access without login data fails. 
• 
If 
show only successfully accessed RFPs is enabled, the OM Configurator adds only RFPs that 
provide configuration information to its database, and displays those RFPs in the OM Configurator 
table.  
• 
The  
use Proxy parameter allows access to RFPs that are located in network segments other than 
the segment that hosts the OM Configurator. The 
IP-address field must contain the address of a RFP 
located in the network segment to be scanned. This RFP works as proxy and must be up and running. 
You initiate the scan process by clicking 
OK button. The OM Configurator adds the results to the table. 
In rare cases, it is possible that a RFP is expected to appear in the table after the scan operation but 
does not. If this occurs, repeat the scan operation.