Mitel Deutschland GmbH 68635RFP36U-01 ユーザーズマニュアル

ページ / 383
 
SIP-DECT OM System Manual 
 
 
240 
7.7.7  APPLYING CONFIGURATION CHANGES 
To apply new or changed configuration to RFP devices, select one or more RFP entries from the table 
and click the 
Send Configuration option in the task bar.  
Note:  You must close the Detail Data window to apply configuration 
changes to an RFP. If the Detail Data window is open, the 
Send 
Configuration option is disabled. 
The OM Configurator displays the 
Protocol settings dialog window. 
The settings in the 
Protocol settings dialog are preset to the values used for the Scan operation or the 
last 
Send Configuration operation. If the values are correct, click OK to transfer the data to the RFP 
device.  
Before sending the data, the system performs a check on mandatory parameters and the validity of 
some parameter values. If this check fails, an error is reported in the Info console. 
The system displays a message in the Info console window indicating success or failure of the data 
transfer operation for each RFP. 
If data is transferred successfully, the OM Configurator displays a checkmark beside the row for the 
corresponding RFP. 
The OM Configurator attempts data transfer three times (two seconds apart) before reporting an error. 
Depending on the network environment and current RFP status, the data transfer may fail in rare cases. 
If a failure to transfer data occurs, click the 
Send Configuration option again to re-initialize the data 
transfer.  
If the data transfer fails, the OM Configurator displays an “X” beside the row for the corresponding RFP. 
 
7.7.8  FACTORY RESET 
RFPs are protected against unauthorized configuration changes by user authentication (user and 
password), which are also used to configure the OMM via web service or OMP.  
To reset a RFP’s configuration, select the RFP entry in the table and click the 
Factory Reset option in 
the task bar. This option is only enabled when a single RFP entry is selected. The option is disabled if 
multiple RFPs are selected.   
The system displays the 
Factory reset settings dialog window. Set the correct login data (user and 
password) and RFP proxy address (if required). The system auto-fills the fields with the values used for 
previous 
ScanSend Configuration or Factory Reset operations. 
 If the specified login (“omm”/”omm”) does not work and the login credentials of the last system the RFP 
was used with are unknown, you can reset the RFP to factory settings by sending a cookie string to the 
OpenMobility manufacturer support and entering the received  reset key. The OM Configurator copies 
the cookie string to the clip board. 
  
7.7.9  SAVING AND LOADING AN RFP LIST 
You can save the configuration of one or more RFPs to a RFP configuration file. Select the RFP entries 
in the table and click the 
Save RFP Config option in the task bar. (Note that if the Detail Data window is 
active, the 
Save RFP Config option is disabled.)