This Appendix contains additional information and examples for configuring your SIP-DECT system.  
10.1 PRE-CONFIGURATION FILE RULES  
The following file format description can be used to administrate the RFP and DECT phone configuration 
with external applications, e.g. an external configuration management tool or a PBX communications 
system. 
The framework of the text file follows strictly defined rules. The main framework is divided in two parts: 
1  An instruction section is used to drive a generic data creation for those fields not filled within data 
sequence section.  
2  A data sequence section defines data record fields. Each of them is explicitly set.  
Layout rules in detail are: 
• 
Comments start with “#”. 
• 
Each record is terminated by the regular expressions “\r” or “\n”. 
• 
Instruction settings are made like: <tag> = <value>.  
• 
Data sequence sections start with the key word “data_sequence”. This key word is  
mandatory for file 
processing to proceed. All instructions must be written before this row. 
• 
Data sequence record fields are separated by colon “;”. Colons have also to be set for empty fields if 
at least one follows which is not empty. Otherwise a position mismatch of fields will occur. 
• 
If fields have several values assigned (that may be true for a few local RFP configuration fields like 
“ntp_address”), they must be separated by comma “,”. 
Notes:  
• 
Because data sequence fields are separated by a colon, the content of that section can be generated 
by a *.csv export of Excel Sheet and copied into the configuration file. 
• 
Instructions are only processed on those fields that are left empty within the data sequence section. 
 
10.1.1 DECT PHONE CONFIGURATION FILE (OMM DATABASE) 
10.1.1.1  Supported Instructions 
Instruction 
Explanation 
start_number 
Numbers can be generated automatically. This instruction defines 
the start value. 
no_of_number 
If “start_number” is given, this instruction defines the maximum of 
numbers which are generated. 
ac (authentication code) 
If set to “number”, “ac” will be equal to number. 
If a value is advised, it will be taken as a start number which will 
be increased for each new record. 
additional_pin 
sip_user 
sip_pw 
sos_number 
If these instructions are set, the value will be taken as default