Mitel Deutschland GmbH 68635RFP36U-01 ユーザーズマニュアル

ページ / 383
 
SIP-DECT OM System Manual 
 
 
46 
• 
Incoming ringing calls which are not yet connected are converted to waiting calls. 
• 
If a third line is open due to a waiting call, that call is released and the line is replaced by the intercom 
call. 
• 
Outgoing calls that have not yet been answered and are in a dialing state, are released. 
• 
If a call is on hold by the B party, the call is released. An on-hold by the B party is difficult to maintain 
while another line has an active audio stream. 
Normally, the user should be able to resume the interrupted calls again when the intercom call is 
finished. However, the calls may fail if several maintained lines collide with call exceptions (e.g., a failed 
call transfer that was maintained in the background). 
Please note: 
Barge-in is rejected if the DECT phone is part of a SOS/alarm call. 
3.35.1.2  Outgoing intercom calls 
A DECT phone can initiate an intercom call. The user must dial the configured access code, followed by 
the destination’s user id / number. 
If a DECT phone generates an intercom call, an Alert-Info header is added to the SIP INVITE: 
• 
the “Alert-Info” header contains “<http://x>info=alert-autoanswer” 
3.35.2 AUTO ANSWER AUDIO SETTINGS 
You can configure global auto-answer settings through the OMM Web service or the OMP. Global 
settings are valid for all DECT phone users in the system, except users who have individual settings. 
Incoming call settings:  
• 
Auto answer allowed (default: true) 
• 
Microphone mute (default: true) 
• 
Warning tone (default: true). A short ringtone is played if there are no active calls. If there is an active 
call in a “barge in” situation, the ringing will be in-band. 
• 
Allow barge in (default: true) 
Outgoing call setting: 
• 
Dial prefix (default: string is empty). Empty string means that an intercom call cannot be initiated by a 
DECT phone. 
3.35.2.1  User-specific incoming call setting 
You can set user-specific settings via OMP, but not the OMM Web Service. Default values for all 