5.4.7.1 Manual Database Import 
Please note: 
A manual import of a database results in a reset of the OMM. 
 
In the 
Manual import section of the Database management page enter the following:  
1  Protocol:  
– To import a database from the Web browser’s file system the protocol 
FILE must be selected. 
– To import a database from an external server select the preferred protocol (e.g. HTTP). 
2  Server: IP address or the name of the external server. 
3  User namePassword (in case of import from an external server): If necessary, enter the account 
data of the server. 
4  File: Path and file name which include the OMM database. If you have selected the FILE protocol, the 
Browse button is displayed and you can to select the file from the file system. 
5  Use common certificate configuration: Enables the use of the system-wide certificate validation 
settings, as configured on the 
System -> Provisioning -> Certificates page (see section 5.4.2.5). 
6  Press the Load button.  
Before the OMM accepts the database, a validation check is performed. If the database is verified as 
valid, the OMM will be reset to activate the new database. 
Please note: 
After the reset, all configuration in the restored database takes effect with the 
exception of the user account settings. The user account settings can be only modified 
locally via the OMM Web service and are never restored by a database import.