Searching 
 
The RFP has lost synchronization to its neighbors. No DECT communication is possible. This phase 
should usually last only for a few seconds after starting up the RFP or the OMM. If this state lasts longer 
or is re-entered after being in a synchronous state this is an indication for a bad location of the RFP. 
Inactive 
 
The RFP has connected to the OMM but the air interface has not been switched on yet. For any RFP 
with activated DECT functionality this phase should last only for a few seconds after starting up the RFP. 
If this state lasts longer this may indicate a hardware failure. 
Not connected 
 
The RFP was configured but has not connected to the OMM yet. Therefore the IP address column is 
empty. 
Software Update available 
 
The RFP is connected to the OMM. The OMM has found new software on the TFTP server. The RFP is 
waiting for the OMM to initiate a reboot. In the meantime is the RFP fully operational. 
 
5.6.2  OMM / RFP SOFTWARE VERSION CHECK 
When the DECT base stations connect to the OMM, they submit their software version. If this version 
differs from the OMM software version and the versions are incompatible, the RFP connection attempt is 
rejected. This could happen when using several TFTP servers with different OpenMobility software 
versions. In this case, the RFP is marked with an error message. Moreover a global error message is 
displayed on the RFP list web page if at least one version mismatch has been found. 
 
5.6.3  CREATING AND CHANGING BASE STATIONS 
1  To configure a new RFP, click the New button on the Base Stations page. 
To change the configuration of an existing RFP click on the 
 icon left beside the base station entry. 