Figure 18: MC-EMA-MPTMP connect to screen 
 
5. 
 
From the MC-EMA main menu (left side of the screen) go to network 
configuration screen and configure: 
a.  Network Frequency  
b.  TX Power 
c.  Number of Hops and Max Retransmission (should be equal) 
d.  Transmission Vector (bandwidth allocation) 
e.  Profile 
6.  Click Verify and chose the unit ID from the dropdown list.  
 
Figure 19: MC-EMA-MPTMP configuration validation  
7. 
Click “configure unit” the configuration is now downloaded to the MCU. 
8.  The MCU reboots with the new configuration and unit ID number. 