16 Appendix D
–Troubleshooting
Symptom
Possible Cause
Action Needed
LED is off
Not connected to power
source or battery is empty
source or battery is empty
1. Verify power cable properly
connected to the MCU PWR
connector.
connector.
2. Verify that the battery or power
supply is connected to the MCU
power cable and to a power outlet.
power cable and to a power outlet.
3. Replace the battery or check the
outlet.
4. Replace the power cable.
LED light is always on
MPTMP
– Not sync with 1PPS
PTP
–Unit is in boot mode
MPTMP :
1. Verify GPS antenna is connected to
AUX connector.
2.
Verify the antenna can “see” the sky.
3. Using the MC-EMA, verify that the
antenna type is configured correctly
(Active/Passive) and change it if
required.
(Active/Passive) and change it if
required.
4. Replace the GPS antenna.
PTP
1. Check the power source
2. Reboot the MCU.
Cannot connect to MCU
using MC-EMA
using MC-EMA
1.
The PC isn’t configured
with a correct static IP
with a correct static IP
2. Using incompatibility MC-
EMA version
(PTP/MPTMP)
(PTP/MPTMP)
3. Un
it isn’t powered up
4. Ethernet cable
isn’t
connected or damaged
data cable
data cable
5. Firewall is blocking traffic
6. ETH port set to auto
negotiation off with 1GE
7. Trying to connect to remote
unit when link is down.
1. Verify your PC is set with a static IP
in the subnet of 192.168.131.xxx.
2. Check that the ETH port is set to
auto negotiation on.
3. Verify the unit is powered up.
4. Verify that the PC ETH port status
isn’t unplugged or disabled.
5. Disable the PC firewall
6. Verify ETH cable is connected to the
PCs ETH port and to the MCU MAIN
connector.
connector.
If needed: replace cables.
7. Verify using PTP-EMA for a PTP
configured MCU and MP2MP-EMA
to MPTMP configured MCU.
to MPTMP configured MCU.
8. Ping the unit.
9. Try to connect to the local MCU and
verify link is up