Microgate WIT005 ユーザーズマニュアル

ページ / 125
 
 
  
 
Microgate Srl 
 
P. 16 / 125 
2.3.1 T
RANSMISSION 
I
MPULSE 
D
URATION 
(R
ADIO 
P
OWER
)
 
 
To  increase  the  reliability  of  the  radio  transmission,  the  data  bundles  of  the  photocell  impulses  are 
transferred repeatedly for a set period of 1.2 seconds. This allows to have redundant information when losing 
some data bundles and to rebuild the event with absolute precision. 
If between two impulses (e.g. start photocell and stop photocell) more than 1.2 seconds elapse, there are of 
course no problems whatsoever.  
Start
Stop
 2,5 sec (> 1.2)
Trasmission of STA for 1,2s
Trasmission of STO for 1,2s
STO Frame
STA Frame
 
Even if the difference is smaller, the second impulse will still be detected, as it will always have a longer "tail" 
than the first one. 
Start
Stop
 0,8 sec (< 1.2)
Trasmission of STA for 1,2s
Trasmission of STO for 1,2s
STO Frame
STA Frame