Toshiba RAS-M10SKV-E ユーザーズマニュアル
Twin–Rotary
Cylinder
DC–Motor
A wide range of efficiency is realised
Inverter Hi-wall
EXTREMELY LOW NOISE LEVELS
DOUBLE ANTI-OXIDANT WITH 7
DOUBLE ANTI-OXIDANT WITH 7
IN 1 PURIFICATION
AUTO DIAGNOSIS AND SELF-
CLEANING FUNCTIONS
MODERN FLAT PANEL
Discreet and unobtrusive, it
delivers high energy efficiency
and complete air purification,
with the 7 in 1 filtering solution.
Thanks to this complete
system, the Hi-wall provides
pure, fresh and healthy air and
ensures absolute comfort in
your home.
delivers high energy efficiency
and complete air purification,
with the 7 in 1 filtering solution.
Thanks to this complete
system, the Hi-wall provides
pure, fresh and healthy air and
ensures absolute comfort in
your home.
Optional Wired Controller for GDV series RBC-SHA1LE2 available
LOW NOISE LEVELS
FLEXIBLE AIR INLET – REAR OR
FLEXIBLE AIR INLET – REAR OR
BELOW THE UNIT
EASY INSTALLATION
SLIMLINE DESIGN
SLIMLINE DESIGN
This ducted multi-split inverter
unit offers reliable and
controllable comfort year-
round. These compact, quiet
units are suitable for a wide
range of residential and light
commercial applications.
unit offers reliable and
controllable comfort year-
round. These compact, quiet
units are suitable for a wide
range of residential and light
commercial applications.
Inverter ducted
Indoor Unit - Reverse Cycle Model
RAS-M07SKV-E
RAS-M10SKV-E
RAS-M13SKV-E
RAS-M16SKV-E
RAS-M22SKV-E
RAS-M24SKV-E
Cooling Capacity
KW
C
2.0 (1.4~2.5)
2.5 (1.1~3.0)
3.5 (1.1~ 4.4)
4.5 (1.4 ~ 4.9)
6.0 (1.20 ~ 6.70)
7.1 (1.4 ~ 7.1)
Heating Capacity
H
2.7 (0.8~3.7)
3.2 (0.9~4.1)
4.2 (0.7~ 6.5)
5.5 (0.8~ 6.9)
7.0 (1.00 ~ 7.50)
8.1 (0.8 ~ 8.1)
Dimension (H x W x D)
mm
275 x 790 x 205
275 x 790 x 205
275 x 790 x 205
275 x 790 x 205
320 x 1050 x 228
320 x 1050 x 228
Weight
Kg
9 9 9 9 13 13
Airflow
158/106 158/106 175/106 206/116 300/183
315
Sound Pressure (L/H)
28-38
28-39
28-40
31-45
33/47
37/49
Liquid Pipe Size
mm
6.35
6.35
6.35
6.35
6.35
6.35
Gas Pipe Size
9.52
9.52
9.52
12.70
12.70
12.7
TOSHIBA AIR CONDITIONING
4
5
Inverter Multi-Split Hi-wall
Indoor Unit - Reverse Cycle Model
RAS-M10GDV-E
RAS-M13GDV-E
RAS-M16GDV-E
Cooling Capacity
KW
C
2.7 (1.1~3.2)
3.7 (1.1~4.2)
4.5 (1.4~4.9)
Heating Capacity
H
4.0 (0.7~5.2)
5.0 (0.7~6.5)
5.5 (0.8~6.9)
Dimension (H x W x D)
mm
230 x 750 x 440
230 x 750 x 440
230 x 750 x 440
Weight
Kg
19
19
19
Airflow
200/111
217/119
217/125
Sound Pressure (L/H)
24-32
25-33
26-34
Liquid Pipe Size
mm
6.35
6.35
6.35
Gas Pipe Size
9.52
9.52
12.70
Inverter Multi-split Ducted
Compact four-way cassette
STANDARD 600mm × 600mm GRID
STANDARD INFRA-RED REMOTE
STANDARD INFRA-RED REMOTE
CONTROL
SLIMLINE DIMENSIONS, FOR
DEMANDING INSTALLATIONS
EASY MAINTENANCE AND
INSTALLATION
This four way cassette has
been designed to grant easy
installation and maintenance.
Its compact design blends with
any room interior and makes it
discreet and unobtrusive.
been designed to grant easy
installation and maintenance.
Its compact design blends with
any room interior and makes it
discreet and unobtrusive.
Indoor Unit - Reverse Cycle Model
RAS-M10SMUV-E
RAS-M13SMUV-E
RAS-M16SMUV-E
Cooling Capacity
KW
C
2.5 (1.1~3.2)
3.5 (1.1~4.4)
4.5 (1.4~4.9)
Heating Capacity
H
3.2 (0.7~5.2).
4.2 (0.7~6.5)
5.5 (0.8~6.9)
Dimension (H x W x D)
mm
268 x 575 x 575
268 x 575 x 575
268 x 575 x 575
Weight
Kg
17
17
17
Airflow
163/120
171/120
183/125
Sound Pressure (L/H)
30-37
30-38
31-40
Liquid Pipe Size
mm
6.35
6.35
6.35
Gas Pipe Size
9.52
9.52
12.70
Inverter Multi-Split Cassettes