9843   Paired   -   Low Capacitance EIA RS-485
 
OUTER SHIELD DRAIN WIRE :
Outer Shield Drain Wire AWG
24 
Outer Shield Drain Wire Stranding
7x32 
Outer Shield Drain Wire Conductor Material
TC - Tinned Copper 
OUTER JACKET:
Outer Jacket Material
PVC - Polyvinyl Chloride 
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter
.360 in.                 
MECHANICAL CHARACTERISTICS:
Operating Temperature Range
-30°C To +80°C 
UL Temperature Rating
80°C (UL AWM Style 2919) 
Bulk Cable Weight
73 lbs/1000 ft.        
Max. Recommended Pulling Tension
105.5 lbs.                
Min. Bend Radius (Install)
3.75 in.                 
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification
CM 
CEC/C(UL) Specification
CM 
AWM Specification
UL Style 2919 (300 V 80°C) 
FLAME TEST:
UL Flame Test
UL1685 UL Loading 
PLENUM/NON-PLENUM:
Plenum (Y/N)
ELECTRICAL CHARACTERISTICS:
Nom. Characteristic Impedance
120  Ohms               
Nom. Capacitance Conductor to Conductor @ 1 KHz
23 pF/ft               
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz
12.8 pF/ft               
Nominal Velocity of Propagation
66 %                   
Nominal Delay
1.6 ns/ft               
Nom. Conductor DC Resistance @ 20 Deg. C
24  Ohms/1000 ft       
Nominal Outer Shield DC Resistance @ 20 Deg. C
2.3  Ohms/1000 ft       
Nom. Attenuation (dB/100 ft)
0.6 (@ 1 MHz) dB/100 ft.          
Max. Operating Voltage - UL
300 V RMS (UL AWM Style 2919) 
Max. Recommended Current
1.54 Amps per conductor @ 25°C 
 