Hardware Installation     
              
 
2-1
Chapter 2 
Hardware Installation  
 
 
2.1 Introduction 
This chapter gives detailed instructions on how to install the subsystem. When installing the 
subsystem, it is necessary to mount the chassis into a rack cabinet and to install hard drives 
and drive trays. Installation into a rack or cabinet should occur before the hard drives or drive 
trays are installed into the subsystem.  
 CAUTION! 
Please note that the installation instructions described in this manual 
should be carefully followed to prevent any difficulties and damage to 
your subsystem. 
 
2.2 Safety 
Precautions 
1.  Disconnect the power cords if the need should arise for cleaning the 
chassis. Do not use liquid or sprayed detergent for cleaning. Use a 
lightly moistened clothe for cleaning.  
2.  Be sure the correct power range (100-120 or 220-240VAC) is supplied 
by your rack cabinet or power outlet. It is highly recommended to 
connect two different power supplies to separate power sources; e.g., 
one to a power outlet, and the other to a UPS system.  
3.  Thermal notice: All drive trays (even if they do not contain a hard 
drive) must be installed into the enclosure. Leaving a drive bay or 
module slot open will severely affect the airflow efficiency within the 
enclosure, and will consequently lead to system overheating. Keep a 
faulty module in place until you have a replacement unit and you are 
ready to replace it.  
4.  Rack-mounting: The subsystem is intended to be rack-mounted. 
Following concerns should be heeded when mounting the enclosure 
into a rack cabinet: 
a.  An enclosure without disk drives can weigh over 60 pounds. 
Two (2) people are required to install or relocate the 
subsystem. Drives should be removed from the enclosure 
before moving the subsystem.