Meridian Data SecurStor iSCSI to SATA-II RAID Subsystem 16i ユーザーズマニュアル

ページ / 91
SecurStor 16i Installation and Hardware Reference Manual  
 
3-4 
 
Amber indicates that a component failure 
has occurred, or inappropriate RAID 
configurations have caused system faults. 
C_Dirty 
Amber 
ON  indicates that there are certain amounts 
of cached data held in memory. 
OFF indicates that the cache is clean.   
Temp. 
Amber 
ON 
indicates that the detected 
CPU/board/chassis temperature has exceeded 
the higher temperature threshold.  
OFF indicates that the detected temperature 
reading is within the preset safe range.  
BBU Link 
Green 
ON indicates the presence of a BBU backup 
module.   
Hst Bsy 
Green 
Rapidly Blinking to indicate traffic on the 
host bus. 
Drv Bsy 
Green 
Rapidly Blinking to indicate traffic on the 
drive channels. 
Restore 
Default 
Green 
Lit Green to indicate the RAID 
configuration default has been successfully 
restored.  The LED state will be invalidated 
after a few seconds.  
 
Note that restoring default will not affect the 
existing RAID configurations of disk drives.    
Table 3-3: Controller LED Definitions 
 
  
Restore NVRAM Defaults – a Push Button 
 CAUTION! 
The Restore NVRAM Default push button is a function that carries some 
risks.  Firmware restoration will not destroy the existing logical drive 
configurations; however, if the existing logical drives cannot be 
adequately associated with host ID/LUNs after firmware default 
restoration, data loss or inconsistencies might occur.    
 
There is a non-latch type push button accessed through a round opening underneath 
the Restore Default LED.  
1.  Before pressing this button to restore firmware defaults, it is highly advised 
to make a list of the existing ID/LUN mapping information.  You will need 
the list for restoring ID/LUN mapping after restoring defaults. Default 
restoration will erase the ID/LUN mapping associations (e.g., which logical 
drive is associated with which host ID/LUN), and it is necessary to restore