Meridian Data SecurStor iSCSI to SATA-II RAID Subsystem 16i ユーザーズマニュアル

ページ / 91
Chapter 3 Subsystem Monitoring 
 
 
 
 
 
 
 
 
 
3-9 
 
 
Upper Threshold 
Lower Threshold 
+3.3V 
+3.6V +2.9V 
+5V 
+5.5V +4.5V 
+12V 
+13.2V +10.8V 
CPU Temperature 
90ºC 5ºC 
Controller Board 
Temperature 
80ºC 5ºC 
Enclosure Ambient 
Temperature 
40ºC 0ºC 
Table 3-7: Default Threshold Values 
 
3.3.2 Failed 
Devices 
If any of the following components fails, the audible alarm will be triggered: 
•  RAID controller module 
•  Cooling fan modules 
•  PSU modules 
•  BBU module 
•  Hard disk drives 
 
 NOTE: 
When temperature exceeds a preset threshold, the controller’s charger 
circuits will stop charging. You will then receive a message that says 
“Thermal Shutdown/Enter Sleep Mode.” When the temperature falls 
back within normal range, the battery will resume charging.  
  
3.4  I
2
C Monitoring 
The operating status of PSU and cooling fan modules are collected through an I
2
C serial bus. 
If either of these modules fails, the failure will be detected and you will be notified through 
the various methods described above. 
 
Formatted: Bullets and Numbering
Deleted: