Chapter 4: Subsystem Connection and Operation 
  
4-7 
 
Figure 4-3: Power Switches 
 
 
 CAUTION! 
Although the PSUs are redundant and a single PSU can provide sufficient power to 
the subsystem, it is advisable to turn both of the power switches on. If only one PSU is 
operating and fails, system operation will be terminated. 
 
4.3.4  Power On Status Check 
Once the subsystem has been powered on, the status of the entire subsystem should be checked to 
ensure that everything is running smoothly and that there are no complications or malfunctions. 
… 
Controller Module LEDs – The controller ready LED should flash green. 
… 
Drive Tray LEDs – The drive status LEDs (that contain hard drives) should all 
lights blue.  
… 
Firmware and RAIDWatch – The overall status of the system may be checked 
using the embedded firmware utility or the RAIDWatch GUI screen. 
… 
Audible Alarm - If any errors occur during the initialization process, the onboard 
alarm will sound in a hastily repeated manner.   
Drive tray LEDs should normally start flashing right after power-on, indicating the RAID 
control unit is attempting to access the hard drives. 
 
 NOTE: 
The subsystem has been designed to run continuously. Even if a component failure 
occurs the fault can be corrected online.