Meridian Data SecurStor iSCSI to SATA-II RAID Subsystem 16i ユーザーズマニュアル

ページ / 91
SecurStor 16i Installation and Hardware Reference Manual  
 
5-12 
 
 
5.5  Replacing a Failed PSU Module 
 
5.5.1  Notes on PSU Module Maintenance 
ƒ  Two (1+1) redundant PSU modules: The subsystem comes with two fully 
redundant, hot-swappable PSU modules. These modules are located at the rear 
section of the subsystem. 
ƒ  PSU canister: Each PSU module is housed in a robust steel canister, with the 
power supply converter unit in the front and two serial-aligned cooling fans in 
the rear section. When the PSU is removed from the chassis, the cooling module 
is also removed. 
ƒ  Printed text on PSU handle: Before you insert a new PSU, make sure that the 
printed text on the PSU handle matches the printed text on a partner PSU. 
Double-check to avoid using a PSU of a different EMD series.  
 
Figure 5-8: Printed Text on PSU Handle 
ƒ  Immediate replacement: When a PSU fails, it should ideally be replaced 
immediately. Do not remove the PSU module unless a replacement is readily 
available. Removing a PSU without a replacement will cause severe disruptions 
to the internal airflow and the subsystem will overheat, possibly causing 
irreparable damage to some of the subsystem components. 
 WARNING! 
Although the subsystem can operate using a single PSU module, it is not advisable 
to run the EMD subsystem with a single PSU module for an extended period of 
time.