Meridian Data SecurStor iSCSI to SATA-II RAID Subsystem 16i ユーザーズマニュアル

ページ / 91
SecurStor 16i Installation and Hardware Reference Manual  
A-4 
 
 
 A.3   Drive Tray Specifications 
Specification 
 
Height 28mm 
Width 110mm 
Depth 218.92mm 
Key Lock 
Yes 
 
A.4   Power Supply Specifications 
 
Specification 
 
Nominal Power 
530W with active PFC 
DC Output 
12.0V: 32A (Max.) 
  5.0V: 32A (Max.) 
  3.3V: 30A (Max.) 
Input Frequency 
47 to 63Hz 
AC Input 
100VAC @ 9A or 240VAC @ 4.5A with PFC 
Power Factor 
Correction 
Yes 
Hold-up Time 
At least 20ms at 115/230VAC full load after a loss of AC input 
Over-temperature 
Protection 
Auto shutdown when lost cooling or exceeded ambient temperature; 
over-voltage protection is also available. 
Cooling Fans 
No fans specific for PSU; heated air is drawn by the cooling fan 
module fixed in the rear section of PSU.   
A.5   Cooling Module Specifications 
Specification 
 
Speed 
High or low rotation speed controlled by firmware proactive mechanisms 
Max. Air Flow (each 
module) 
High speed: 90 CFM 
Low speed: 70.7 CFM 
Input Power 
13.2W max. 
Input Current 
1.1A max. 
Rated Voltage 
DC 12V 
Temperature 
Operating: -10 to +70ºC 
Storage: -30 to +70ºC 
Acoustic Noise 
High speed: 51dB Max. 
Low speed: 46dB Max.