ELECTRICAL REQUIREMENTS - U3, U3A, U333, U38, U3833
CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up.
U333 & U3833  requires 3-wire, grounded service 
rated 240  volt  ac, 35 amp or 440 volts ac, 30 amp 
for U333,three phase, 60 Hz or 380 volts ac, 30 amp 
for U3833,  three phase, 50 Hz.
U3 &  U38 requires 3-wire, grounded service rated 
120/208 or 120/240 volts ac, U3/SRU-30 amp,U38-40 
amp, single phase, 60 Hz.
U3A models require 2-wire, grounded service rated 
230 volts ac, 30 amp, single phase, 50 Hz.
U3833 requires 4-wire, grounded service rated 
380 volts ac or 440 volts ac, 30 amp, three phase, 
50 Hz.
GREEN
GREEN
L1, L2, L3, are the 3 phases
V1 = Phase to phase voltage,
 
between any 2 phases.
V2 = Phase to neutral voltage,
 
any phase to neutral.
 SYSTEM
VOLTAGE 
 V1 
 V2 
 208 
208  120 
 240 
240  139 
 380 
380  220
 440 
440  254
 
P1842
P1844
42769  041910
GREEN
GREEN
L2 RED
WHITE
NEUTRAL
L1 BLACK
120V A.C.
208 OR 
240V A.C.
RED
BLACK
BLUE
120V A.C.
208V OR 240V
380V OR 440V
208V OR 240V
380V OR 440V
208V OR 240V
380V OR 440V
P1841
P1843
L2
L3
L1
RED
BLACK
L1
L2
L3
N
WHITE
BLUE
(NEUTRAL)
U3A Requires 2-wire, gorunded service rated 230 
volts ac, 32 Amps, single phase, 50 Hz.
FACTORY WIRED
U3A Requires 4-wire, 3-phase grounded service 
rated 400 volts ac, 15 amp, 3 phase, 50 Hz.
FIELD WIRING
GREEN
GREEN
RED
BLACK
L1
L2
230V A.C.
ELECTRICAL REQUIREMENTS - U3A (UK)
CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up.