Multiquip Cordless Sander EHTX44Y5 ユーザーズマニュアル

ページ / 50
page 46 — eHTx44y RIDe-ON TROWeL • OpeRaTION maNuaL — Rev. #0 (01/16/13) 
trOuBleSHOOtinG
Troubleshooting (Ride-On Hydraulic Trowel)
Symptom
possible problem
Solution
Safety stop switch not functioning.
Other problems?
Consult engine manufacturer’s manual.
Loose wire connections?
Check wiring. Replace as necessary.
Bad contacts?
Replace seat cushion (contains the switch).
If trowel “bounces, rolls concrete, or makes uneven 
swirls in concrete”..
Blades?
Make certain blades are in good condition, not 
excessively worn. Finish blades should measure no 
less than 2"" (50mm) from the blade bar to the trailing 
edge, combo blades should measure no less that 3.5"" 
(89mm). Trailing edge of blade should be straight and 
parallel to the blade bar.
Spider?
Check that all blades are set at the same pitch angle 
as measured at the spider. A fi eld adjustment tool is 
available for height adjustment of the trowel arms (see 
Optional Equipment)..
Bent trowel arms?
Check the spider assembly for bent trowel arms. If one 
of the arms is even slightly bent, replace it immediately.
Trowel arm bushings?
Check the trowel arm bushings for tightness. This can 
be done by moving the trowel arms up and down. If 
there is more than 1/8"" (3.2 mm) of travel at the tip of 
the arm, the bushings should be replaced. All bushings 
should be replaced at the same time.
Thrust collar?
Check the fl atness of the thrust collar by rotating it on 
the spider. If it varies by more than 0.02"" (0.5 mm) 
replace the thrust collar.
Thrust collar bushing?
Check the thrust collar by rocking it on the spider. If it 
can tilt more than 1/16"" (1.6 mm) [as measured at the 
thrust collar O.D.], replace the bushing in the thrust 
collar.
Thrust bearing worn?
Check the thrust bearing to see that it is spinning freely. 
Replace if necessary. 
Blade pitch?
Check blades for consistent pitch. Adjust per 
Maintenance Section instructions if necessary.
Machine has a perceptible rolling motion while 
running.
Spider Finger Screws?
Adjust per procedure in Maintenance Section.
Yoke?
Check to make sure that both fi ngers of the yoke press 
evenly on the wear cap. Replace yoke as necessary.
Blade Pitch?
Check to ensure that each blade is adjusted to have the 
same pitch as all other blades. Adjust per maintenance 
section in manual.