Overview 
BT100 Installation and Operation Manual 
 
Ingress Control Switch 
The ingress control switches (ICS) provide return-path signal attenuation or cutoff in the 
BT100. An ICS is required for each output port. Therefore the standard four output BT100 
requires four ICS’s. Switching is accomplished through the frequency agile LIFELINE 
status-monitoring transponder, which you can purchase directly from AM Networks.  
Figure 2-12 illustrates the LL-BTA-HMS and the required cable connections to the electronics 
chassis. 
Figure 2-12  
LL-BTA-HMS status monitor 
 
The ICS provides a means of isolating sources of ingress from a centralized location. Using a 
downstream command through the LIFELINE status-monitoring system, you can attenuate the 
return path through the amplifier by 6 dB or by 38 dB. By reducing the ingress level at the 
headend or monitoring point, you can further isolate the ingress source. After you isolate an 
ingress source to the last possible amplifier, node, or line extender, you can shut the return path 
off at that location. This limits the impact of the ingress on the remainder of the network while 
eliminating the source of ingress.