Mitsubishi Electronics Mitsubishi Digital Electronics Video Gaming Accessories FX3G ユーザーズマニュアル
123
FX
3G
/FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
4 Devices in Detail
4.9 Data Register and File Register [D]
1
In
trodu
ct
ct
ion
2
O
ver
vi
ew
3
In
st
ru
ct
ion
Li
st
4
D
evices
in D
etail
etail
5
Specifi
ed t
he
he
D
evice &
C
onst
ant
ant
6
Bef
ore
ore
Pr
ogr
am
am
m
ing
7
B
asic
In
st
ru
ct
ion
8
FNC0
0-F
0-F
NC0
9
Pr
ogr
am
Flow
am
Flow
9
FN
C
C
10-FN
C
19
Mo
ve
ve
&
Co
mp
are
are
10
FNC2
0-F
0-F
NC2
9
Ar
ith.
&
&
Logic
O
per
ati
ati
on
4.9
Data Register and File Register [D]
Data registers are devices for storing numeric data. File registers are handled as the initial values of data registers.
Each data register or file register stores 16-bit data (whose most significant bit specifies the positive or negative sign).
Combined two data registers or file registers can store 32-bit numeric data (whose most significant bit specifies the
positive or negative sign).
Each data register or file register stores 16-bit data (whose most significant bit specifies the positive or negative sign).
Combined two data registers or file registers can store 32-bit numeric data (whose most significant bit specifies the
positive or negative sign).
→ For the functions and operations of file registers, refer to Subsection 4.9.4.
4.9.1
Numbers of data registers and file registers
The table below shows numbers of data registers and file registers. (Numbers are assigned in decimal.)
1. FX
3U
/FX
3UC
PLC
2. FX
3G
PLCs
*1.
This area is not latched (battery backed). It can be changed to the latched (battery backed) area by setting
parameters.
parameters.
*2.
This area is latched (battery backed). It can be changed to the non-latched (non-battery-backed) area by
setting parameters.
setting parameters.
*3.
The latch (battery backup) characteristics cannot be changed using parameters.
*4.
Data registers D1000 and later can be used as file registers in units of 500 points by setting parameters.
*5.
These registers can be changed to the latched type by the parameter setting when the optional battery is
used. However, the latched range cannot be set.
used. However, the latched range cannot be set.
When computer link PCs or parallel link is used, some data registers are occupied for the link.
→ Refer to the Data Communication Edition.
Data registers
File registers
(latched (battery
backed) type)
General type
Latched (battery backed)
type
(backed up by battery
against power failure)
against power failure)
Fixed latched (battery
backed) type
(backed up by battery
against power failure)
against power failure)
Special type
D0 to D199
200 points
*1
D200 to D511
312 points
*2
D512 to D7999
7488 points
7488 points
*3*4
D8000 to D8511
512 points
D1000
*4
and later
7000 points maximum
Data registers
File registers
(latched (EEPROM
keep) type)
General type
Latched type
(EEPROM keep)
General type
Special type
D0 to D127
128 points
D128 to D1099
972 points
D1100 to D7999
6900 points
*5
D8000 to D8511
512 points
D1000
*4
and later
7000 points maximum