Mitsubishi Electronics Mitsubishi Digital Electronics Video Gaming Accessories FX3G ユーザーズマニュアル

ページ / 936
336
FX
3G
/FX
3U
/FX
3UC
 Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
13 High Speed Processing – FNC 50 to FNC 59
13.1 FNC 50 – REF / Refresh
13.1
FNC 50 – REF / Refresh
Outline
This instruction immediately outputs the latest input (X) information or the current output (Y) operation result in the
middle of a sequence program.
1. Instruction format
2. Set data
3. Applicable devices
S1: X000, X010 or X020:
Up to the final input number (whose least significant digit number is "0")
S2: Y000, Y010 or Y020:
Up to the final output number (whose least significant digit number is "0")
S3: FX
3U
/FX
3UC
 PLCs:
K8 (H8) or K16 (H10): Up to K256 (H100) (which is a multiple of 8)
FX
3G
 PLC: 
K8 (H8) or K16 (H10): Up to K128 (H80) (which is a multiple of 8)
Operand Type
Description
Data Type
Head bit device (X or Y) number to be refreshed
Bit
n
Number of bit devices to be refreshed
(FX
3U
/FX
3UC
: multiple of 8 in the range from 8 to 256,
 FX
3G
: multiple of 8 in the range from 8 to 128)
16-bit binary
Oper-
and 
Type
Bit Devices
Word Devices
Others
System User
Digit Specification
System User
Special 
Unit
Index
Constant
Real 
Number
Charac-
ter String
Pointer
X
Y
M T C S D….b KnX KnY KnM KnS T C D R U…\G… V Z Modify
K
H
E
"…"
P
S
1
S
2
n
S
3
S
3
P
FNC 50
REF

Mnemonic
Operation Condition
16-bit Instruction
5 steps
REF
REFP
Mnemonic
Operation Condition
Continuous
Operation
Pulse (Single)
Operation
32-bit Instruction
D
D