Outline
This instruction executes PID control which changes the output value according to the input variation.
→ For details, refer to the Analog Control Edition.
1. Instruction format
2. Set data
3. Applicable devices
S
: This function is supported only in FX
3U
/FX
3UC
 PLCs.
Explanation of function and operation
1. 16-bit operation (PID)
When the target value 
, measured value 
, and parameters 
 to 
+6 are set and a program is
executed, the operation result (MV) is stored to the output value 
 at every sampling time 
.
Operand type
Description
Data type
Data register number storing the target value (SV)
16-bit binary
Data register number storing the measured value (PV)
16-bit binary
Data register number storing a parameter
16-bit binary
Data register number storing the output value (MV)
16-bit binary
Oper-
and 
Type
Bit Devices
Word Devices
Others
System User
Digit Specification
System User
Special 
Unit
Index
Con-
stant
Real 
Number
Charac-
ter String
Pointer
X Y M T C S D….b KnX KnY KnM KnS T C D R U…\G… V
Z Modify K H
E
"…"
P
3 3
S
3 3
S
3 3
3 3
S
FNC 88
PID
Mnemonic
Operation Condition
16-bit Instruction
9 steps PID
Mnemonic
Operation Condition
Continuous
Operation
32-bit Instruction
S
1
 ‚
S
1
S
1
 ‚
S
2
S
3
S
1
 ‚
D
S
1
 ‚
S
1
S
1
 ‚
S
2
S
2
 ‚
S
3
S
1
 ‚
D
S
1
S
2
S
3
S
3
D
S
3
Command
input
FNC 88
PID
S
3
S
2
S
1
D
Target value (SV)
Measured value (PV)
Parameter