Meridian Data Excel / Meridian Data Computer Drive 1 ユーザーズマニュアル

ページ / 139
110
 
 
E
XCEL 
M
ERIDIAN 
D
ATA
 
 
Event Notification Response 
When you select Event Notification, Astra ES sends popup and/or email messages regarding its status. The 
messages you see depend on your notification selection and what is currently happening in the Astra ES. 
The table below cites: 
• 
Reported Events 
– Events that require you to take action 
• 
Corrective Actions 
– The action you should take in response to the event 
 
Reported Event 
Corrective Action 
Battery 
Battery temperature is 
above the threshold 
The battery is too hot. Verify proper airflow around 
the through the Astra ES. If airflow is OK, replace the 
battery.  
Battery temperature is 
normal 
Normal. 
Battery capacity is below 
the threshold 
Battery is drained. Run battery reconditioning.  
Battery capacity is normal  Normal. 
Battery is discharging 
Battery is undergoing reconditioning. 
Battery is charging 
Battery is being recharged. 
Battery reconditioning is 
complete 
Battery reconditioning is finished. 
Battery is malfunctioning  Run battery reconditioning. If this message 
reappears, replace the battery. 
Battery reconditioned 
successfully 
Battery reconditioning is finished. 
Battery reconditioning 
has failed 
Replace the battery. 
Battery is reaching end of 
life 
Replace the battery. 
Battery is removed 
The battery was disconnected or removed. Reinstall 
the battery. 
Battery charging failed 
Replace the battery. 
Battery reconditioning 
started 
Battery reconditioning has begun. 
Battery recondition 
terminated 
The battery was disconnected or removed during 
reconditioning. Reinstall the battery. 
(Battery Events)