Matrox Electronic Systems II ユーザーズマニュアル

ページ / 136
50      Chapter 4: Using multiple Matrox Meteor-II boards
If you are installing an additional Matrox Meteor-II board on 
Matrox 4Sight, the module already installed has the setting 
fixed at 0; therefore, the setting of the additional module must 
be at a setting other than 0 or 4. 
Grabbing simultaneously from different 
boards
You can simultaneously grab images from cameras attached to 
different Matrox Meteor-II boards. To grab at exactly the same 
time, the cameras must be genlocked (synchronized) and their 
corresponding digitizer configuration formats must be the 
same. Note that this restriction does not apply to Matrox 
Meteor-II /1394
The number of cameras from which you can simultaneously 
grab is determined by the PCI bandwidth available in your 
computer. 
.
Grabbing from two genlocked cameras
Matrox Meteor-II
Matrox Meteor-II