Matrox Electronic Systems II ユーザーズマニュアル

ページ / 136
Matrox Meteor-II /Standard grab section      57
Trigger signals connected to the OPTOTRIG- and OPTOTRIG+ 
input pins, pass through an opto-coupler, a device that protects 
the board from outside surges; OPTOTRIG- is usually 
connected to the ground of the trigger source. The voltage 
difference across OPTOTRIG+ and OPTOTRIG- must be 
between 4.05 V and 9.16 V for logic high, and between -5.0 V 
and 0.8 V for logic low. Refer to Appendix B for the pinouts of 
these signals on your respective form factor.
User bits
Matrox Meteor-II /Standard supports four auxiliary user bits 
through the video input connector: two input and two output. 
These are available for controlling external events such as a 
strobe light. User bits are programmed using the MIL-Lite 
command MdigControl().
Using the auxiliary power supply
Matrox Meteor-II /Standard can supply power to your camera. 
Use the 4-pin power cable provided with your board to connect 
to the power supply of your computer. The operating  voltage 
can be set to either 5 V or 12 V, but the current drawn by all 
cameras is limited to 1.5 A. The circuit uses an auto-resettable 
fuse. For further information on connecting to the auxiliary 
power supply connector, see the section, Connecting Matrox 
Meteor-II /Standard to the auxiliary power supply input
 in
 
Chapter 2, and Appendix B. Note that this input is not available 
on the CompactPCI and PC/104-Plus form factors.