60      Chapter 5: Matrox Meteor-II hardware reference
You can change the gain value using the MIL-Lite 
MdigControl() command. The supported gain factors are as 
follows:
Triple A/D converter
A triple A/D converter with external reference generation and 
sync slicing is used for component RGB digitization. The 
converter can be operated at up to 30 MSPS. 
In addition, the converter’s black and white reference levels can 
be adjusted individually. The black and white reference levels 
can be adjusted between 0.6 V to 1.6 V and 1.6 V to 2.6 V 
respectively, in increments of 10.23 mV (98 distinct 
adjustments).
Use the MIL-Lite MdigReference() command to set the black 
and white reference levels.
PSG
The Programmable Synchronization Generator (PSG) is 
responsible for managing all timing and synchronization 
signals.
Phase-locked loop
The high-performance, low-jitter phase-locked loop (PLL) uses 
frequency synthesis techniques to generate the clock signal, 
when necessary.
The PLL can use the following sources as a reference:
Input video signal 
amplitude 
(excluding sync)
Total input video 
signal amplitude 
(including sync)
Required 
gain 
setting
MIL
0.0 V up to 0.5 V
0.0 - 0.7 Vpp
4
M_GAIN3
0.5 V up to 0.7 V
0.7 - 1.0 Vpp
2.8 (default) M_GAIN2
0.7 V up to 1.0 V
1.0 - 1.4 Vpp
2
M_GAIN1
1.0 V up to 1.5 V
1.4 - 2.1 Vpp
1.3
M_GAIN0
1.5 V up to 2.0 V
2.1 - 2.9 Vpp
1