Signal Connections 
Signals are sent between the HFG2.0 and the user’s controller through 
the integral 17-wire signal harness. See Table 1-4 for the wire list for this 
harness. See Figure 1-12 for the system signal wiring diagram. 
 
WIRE COLOR 
FUNCTION 
AWG 
WHITE/ORANGE/YELLOW Serial/RX 
In 
20 
WHITE/ORANGE/BLUE Serial/TX 
Out 
20 
WHITE/ORANGE/GREEN Serial 
RETURN 
20 
BLACK OVER 
TEMP 
Alarm 
20 
WHITE/BLACK 
OVER TEMP Alarm RETURN 
20 
ORANGE FAULT 
Alarm  20 
WHITE/ORANGE 
FAULT Alarm RETURN 
20 
VIOLET RUN 
Command 
20 
WHITE/VIOLET 
RUN Command RETURN 
20 
GRAY RESET 
Command 
20 
WHITE/GRAY 
RESET Command RETURN 
20 
BROWN Position 
Demand 
20 
WHITE/BROWN 
Position Demand RETURN 
20 
YELLOW Position 
Feedback 
20 
WHITE/YELLOW 
Position Feedback RETURN 
20 
BLUE Motor 
Current 
20 
WHITE/BLUE 
Motor Current RETURN 
20 
Table 1-4.  Wire List for HFG2.0 System Signal Harness