Fujitsu MAN3367 ユーザーズマニュアル

ページ / 302
C141-E124-01EN
4 - 49
4.2.4.5 Total read bytes processed (Page 03, Code 0005)
                             Bit
Byte
7
6
5
4
3
2
1
0
4
5
(MSB)
X'0005' (Parameter code)
(Total Bytes Processed)
(LSB)
DU
DS
TSD
ETC
TMC
LBIN
LP
6
0
0
0
0
0
0
0
0
7
X'0A' (Parameter Length)
8
(MSB)
9
16
Total Write Bytes Processed (10 bytes)
17
(LSB)
The Total Read Bytes Processed indicates the total processed bytes during read operation.
The bytes includes the total processed bytes during verify operation.  (page X'05', Parameter code
X'0005')
4.2.4.6 Total posted unrecoverable read errors (Page 03, Code 0006)
                             Bit
Byte
7
6
5
4
3
2
1
0
4
5
(MSB)
X'0006' (Parameter code)
(Total Posted Unrecoverable Errors)
(LSB)
DU
DS
TSD
ETC
TMC
LBIN
LP
6
0
0
0
0
0
0
0
0
7
X'04' (Parameter Length)
8
(MSB)
9
10
Counter Value
11
(LSB)
The Counter Value indicates the count of all posted unrecovered errors (03/xx/xx) to the interface
during read operations.  The value includes the count of all posted unrecovered verify errors (page