discharge line or between the pump and relief valve.  FMC recommends that the 
discharge be returned to the tank or drain, not back into the pump suction line. 
5.  It is recommended that a start-up bypass line and valve be installed to allow flow 
to bypass the relief valve.  This allows the pump to start in an unloaded condition 
(no discharge pressure). 
4.6 
Multiple Pump Systems 
 
Special consideration must be taken to avoid vibration, pulsation, or uneven flow 
distribution problems when operating multiple reciprocating pumps using common 
suction and discharge piping headers.  It is recommended that the user contact FMC or 
experienced industry consultants for assistance with the design of the system and pump 
installation in these situations. 
5.0 
How to Start a Pump 
 
CAUTION: Always take special precautions when starting a pump for the first time or 
after any extended shutdown.  Never assume that someone else has properly 
prepared the pump and system for operation.
  Always check each component of the 
system prior to every start-up. 
The checklist that follows is intended to be a general guide for starting a pump in a 
typical installation.  Every installation is different, and each will have different 
requirements to insure safe and successful operation.  It is the responsibility of the 
operator to determine the correct start-up procedure for each installation.
 
1.  Insure that the drain plug(s) on the bottom of the pump crankcase have been 
installed and are tight.  Insure that the oil level sight glass, if equipped, has been 
properly installed. 
2.  Check the oil level to insure that the pump is properly filled and that the oil has not 
been contaminated with water or other contaminants.  NOTE: FMC pumps are 
shipped with no oil in the power frame and must be filled to the proper level with 
the proper grade of oil prior to start-up. 
NOTICE: The L16 model pump requires 80W90 non-detergent gear oil.  For all other 
pumps (L06 through L12) use Table 2 provided in Section 6.0 for selecting the correct 
type of oil for your service. 
  Pump model L06 & L06 HD requires 2 quarts (1.9 liters) of oil 
  Pump model L09 & L09 HD requires 2 1/4 quarts (2.1 liters) of oil 
  Pump model L11 & L11 HD requires 4 quarts (3.8 liters) of oil 
  Pump model L12 & L12 HD requires 4 quarts (3.8 liters) of oil 
  Pump model L16 requires 10 quarts (9.5 liters) of gear oil