FIELD CONTROLS Heat Recovery Ventilator FC95HRV. ユーザーズマニュアル

ページ / 32
12
STALE AIR
TO OUTSIDE
FRESH AIR
FROM OUTSIDE
STALE AIR
FROM INSIDE
FRESH AIR
TO INSIDE
14
3
/
4
"
(375)
1
9
"
(4
8
3
)
*
All Duct Connections 6"(150mm)
FILTERS
BLOWERS
*NOTE: Front clearance 
 of 25 inches (635 mm)
is recommended 
 for servicing unit.
MOTOR
ENTHALPIC CORE
33-5/8"
(850)
BALANCING
DAMPER
BALANCING
DAMPER
CORE
Model FC150ERV
DIMENSIONS FC150ERV
inches (mm)
Date: ___________________________________________
Tag: _____________________Qty:___________________
Project: _________________________________________
Engineer: _______________________________________
Contractor: ______________________________________
Supplier: ________________________________________
Quote#: _________________________________________
Submitted by: ____________________________________
All units conform to CSA and UL
standards.
Static Pressure (in w.g.)
A
ir
Fl
ow
(c
fm
)
20
40
60
80
100
120
140
160
180
200
220
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
1 - Low speed
2 - High Speed 
2
1
*Sensible Efficiency – thermal **Latent Efficiency – moisture
Note: Effectiveness - based on temp. differential between the 2 airstreams
Efficiency – takes into account all power inputs
Performance
Net supply air flow in cfm (L/s) against external static pressure
E.S.P
(external static pressure)
[cfm (L/s)]
@ 0.1" (25 Pa)
151 (71)
@ 0.2" (50 Pa)
140 (66)
@ 0.3" (75 Pa)
131 (62)
@ 0.4" (100 Pa)
123 (58)
@ 0.5" (125 Pa)
107 (50)
@ 0.6" (150 Pa)
98 (46)
@ 0.7" (175 Pa)
81 (38)
@0.8 " (200 Pa)
60 (28)
Sensible Effectiveness
@ 64 cfm (30 L/s)
32°F (0°C)
81%
*Sensible Efficiency
@ 64 cfm (30 L/s)
32°F (0°C)
69%
Total Efficiency
50%
@ 64 cfm (30L/s)
95°F (35°C)
47%
VAC @ 60HZ
120
WATTS / Low speed.
63
WATTS / High speed
173
Amp rating
1.4
LATENT RECOVERY/MOISTURE TRANSFER CORE
The cross-flow energy recovery core transfers heat and water vapor
between the two airstreams. It is easily removed for cleaning or service.
MOTORS AND BLOWERS
Each air stream has one centrifugal blower driven by a common PSC
motor. 5 speed fan operation.
FILTERS
Washable air filters in exhaust and supply air streams.
MOUNTING THE ERV
Four threaded inserts at corners of case designed to accept the "S" hooks
and hanging straps supplied with the unit.
CASE
Twenty gauge prepainted galvanized steel (G60) for superior corrosion
resistance. Insulated to prevent exterior condensation. Door balancing
ports.
WEIGHT
75 lbs. (34Kg)
SHIPPING WEIGHT
77lbs. (35Kg)
ELECTRONICS
•Built-in Relay for Interfacing to furnace
OPTIONAL CONTROLS
# DHVC Ventilation Control
• 2 Speed Fan setting (Low/High) • Dehumidistat
#HHSC
Healthy Home System Control
• Automatically activates the unit to deliver fresh air into your home
#DH1
Dehumidistat
• Initiates high speed ventilation when the indoor humidity level exceeds
the set point
OPTIONAL TIMERS
#VTC
Ventilation Timer Control - Initiates high speed ventilation
for 20, 40, or 60 minutes, (3 wire) 20 gauge wire (min.) 100'
length
OPTIONAL ACCESSORIES
#WH 186 Weatherhoods, Two - 6” (150 mm) c/w 1/4” (6 mm) mesh
screen
WARRANTY
Units carry a five (5) year warranty
on the enthalpic (ERV) core and a 5
year replacement parts warranty.