FIELD CONTROLS Heat Recovery Ventilator FC95HRV. ユーザーズマニュアル
The timer will override the Operational Mode (regardless of the
setting) and initiate high speed ventilation. Upon completion of the
timer cycle, the HRV/ERV returns to your selected Operational
Mode and speed setting.
Lifestyle 20/40/60 Minute Timer
Initiates high speed ventilation for 20, 40 or 60 minutes. The
20/40/60 Minute Status Lights indicate high speed operation.
Lockout Mode is useful if you wish to disable the timer. Set
Lockout Mode is useful if you wish to disable the timer. Set
lockout by holding the Select Button for 5 seconds. Unlock by
holding for 5 seconds.
Optional Vent Timer Control (VTC)
Select Button
20/40/60 Minute
Status Lights
Status Lights
If the system does not have a main control
installed, the HRV/ERV Terminal Block must have
a jumper installed between 2 (ON) and 3 (RED).
Refer to “Operating the HRV/ERV without a Main
Control” in this manual.
installed, the HRV/ERV Terminal Block must have
a jumper installed between 2 (ON) and 3 (RED).
Refer to “Operating the HRV/ERV without a Main
Control” in this manual.
ATTENTION
6